2015. Septiembre 2016

Autoconsumo con y sin almacenamiento bajo el RD 900/2015 Septiembre 2016 Jean-Francois Picard [email protected] KOSTAL Solar Electric Ibérica S.L.

3 downloads 298 Views 6MB Size

Recommend Stories


SEPTIEMBRE 2016
ABRIL / SEPTIEMBRE 2016 CAMPU S CU LTU RAL E XPO SIC IO N E S EXPOSICIONES PERMANENTES Entrada libre AMA LA PAZ Y ODIA LA GUERRA Conjunto de fr

LECTIO DIVINA SEPTIEMBRE 2015
LECTIO DIVINA SEPTIEMBRE 2015 Lectio Divina: Martes, 1 Septiembre, 2015................................................................ 2 Lectio Divi

Story Transcript

Autoconsumo con y sin almacenamiento bajo el RD 900/2015 Septiembre 2016

Jean-Francois Picard [email protected] KOSTAL Solar Electric Ibérica S.L. www.kostal-solar-electric.com

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Agenda Breve presentación de la empresa KOSTAL Introducción al autoconsumo FV según el RD 900/2015 Aspectos legales Esquemas conexionado Dimensionado Ejemplo Autoconsumo tipo 2 Gama de inversores PIKO Monofásico (desde 1,5 kW hasta 4,2 kW) Trifásicos (desde 4,2 kW hasta 20 kW) PIKO BA Sensor, Sensor de corriente de consumos PIKO Battery: Autoconsumo con almacenamiento Monitorización PIKO Solar Portal PIKO App

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Presentación de la empresa

Presencia global 15,000 empleados 39 direcciones 17 países 4 continentes 2.000 m€

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Presentación de la empresa

KOSTAL Automobile Electrical

Módulos de techo, de columna de dirección, de consola central Sistemas eléctrico de tablero Controladores de puertas Controladores de asientos Elementos de control e interruptores

KOSTAL Industrial electronics KOSTAL Kontakt Systeme

KOSTAL Industrie Elektrik

KOSTAL SOMA

Sistemas de contacto Sistemas de conexión y enchufes

Cajas de módulo fotovoltaico Variadores frecuencia Electrónica de control y medición Inversores fotovoltaicos

Automatización Tecnología de pruebas Tecnología de medición

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Presentación de la empresa

KOSTAL Automobile Electrical

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Presentación de la empresa

KOSTAL Automobile Electrical

El éxito de nuestros clientes asegura el éxito de KOSTAL! 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Presentación de la empresa

KOSTAL Industrie Fotovoltaica

Electrónica de potencia y control de motores Inversores fotovoltaicos PIKO

Electrónica de control

KOSTAL Solar Electric GmbH

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Presentación de la compañía Presentación

de la empresa

Hagen, Alemania Oficina central de KOSTAL Industrial Electronics Desde Abril 2005 Superficie de 87,000 m², de los cuales 14,700 m² están edificados. Aprox. 450 empleados (más de 200 en KOSTAL Industrial Electronics, el resto en KOSTAL Kontakt Systeme GmbH)

Hagen Schalksmühle Guyancourt

Freiburg i.Br.

Turin

Thessaloniki Valencia

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Presentación de la empresa

Valencia, España KOSTAL Solar Electric Ibérica S.L. Desde Enero de 2009 Oficina técnico comercial para los mercados de España y Portugal Ventas, Soporte técnico, Formación

Hagen Schalksmühle Guyancourt

Freiburg i.Br.

Turin

Thessaloniki Valencia

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Autoconsumo

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Autoconsumo

AUTOCONSUMO

VENTA A RED

Generación FV = Ahorro de energía

Generación = Venta de energía

Contador Producción

Tarifa de venta €/Kwh Vertidos a la red

kW Tarifa de compra € / kWh Tarifa de compra €/kWh (según contrato)

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Normativa autoconsumo RD 900/2015, breve resumen Modalidad Autoconsumo TIPO 1 Potencia contratada del cliente ≤ 100kW Los excedentes son permitidos, pero no remunerados 1 único titular (sujeto Consumidor) Instalación sujeta al RD 1699/2011 Sin registro en el RAIPRE (Registro Autonómico de Instalaciones de Producción en Régimen Especial) Sin Aval Modalidad Autoconsumo TIPO 2 Sin mínimos, ni máximos de potencia contratada del cliente Los excedentes son permitidos, y remunerados a precio pool Titular Consumidor puede diferir del titular Productor (pero un único titular Productor) Instalaciones ≤ 100kW FVp sujetas al RD 1699/2011 Instalaciones >100kW FVp sujetas al RD1955/2000 (y medición de consumo total) Con registro en el RAIPRE (Registro Autonómico de Instalaciones de Producción en Régimen Especial) Aval (10 €/kW) Y en cualquier caso Potencia FVp ≤ Potencia contratada del cliente Medición de la producción FV (telegestión y telemedida.) Registro de Autoconsumidores (MINETUR) 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Normativa autoconsumo RD 900/2015, breve resumen Acumulación Tanto para la modalidad TIPO 1 como TIPO 2, se permite explícitamente el uso de baterías. Estas instalaciones se denominan “gestionables”. Se asocia unos cargos específicos a las instalaciones “gestionables”. Pero este caro solamente se aplicara cuando se consume más de la potencia contratada!

Instalación FV aislada No se aplica a las instalaciones aisladas de la red (¡sin conexión física alguna!) Art. 3.1.j): aquella en la que no existe en ningún momento capacidad física de conexión eléctrica con la red de transporte o distribución ni directa ni indirectamente a través de una instalación propia o ajena. Las instalaciones desconectadas de la red mediante dispositivos interruptores o equivalentes no se considerarán aisladas a los efectos de la aplicación de este real decreto.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Normativa autoconsumo RD 900/2015, breve resumen

RD 900/2015 Autoconsumidor tipo 1 : Consumidor Pp ≤ Pc ≤ 100kW RD 1699/2011

Autoconsumidor tipo 2 : Consumidor y Productor RD 1699/2011 ( Pp ≤ 100 kW) RD 1955/2000 (Pp > 100 kW) – Ley 54/1997 RD 413/2014 (RAIPRE)

Distribuidora eléctrica Autoconsumidor B.T. Pc < 100kW

Autoconsumidor A.T. Pc ≤ 100 kW Pc > 100 kW

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Normativa autoconsumo RD 900/2015 Equipos de mediciones

Tipo 1 Contador de producción obligatorio Contador punto frontera obligatorio Contador consumo opcional

Contador Producción FV

Contador Punto frontera

Contador Consumos

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Autoconsumo, esquema unifilar B.T. según MT 3.53.01. Ed. 05. Iberdrola (03/16)

Para la conexión de una instalación de generación a la red de Iberdrola Distribución de Baja Tensión se aplicará las condiciones técnicas de conexión y funcionamiento recogidas en el Real Decreto 1699/2011 que regula la conexión a red de instalaciones de producción de pequeña potencia.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Tipo 2 Si ≤ 100kWp & 1 solo titular (consumidor = productor) Contador consumo opcional Contador punto frontera obligatorio Contador Producción FV

Normativa autoconsumo RD 900/2015 Equipos de mediciones Otros casos… Contador consumo obligatorio Contador punto frontera opcional Contador Producción FV

Contador Punto frontera

Contador Consumos

Contador Punto frontera

Contador Consumos

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Autoconsumo, esquema unifilar A.T. según MT 3.53.01. Ed. 05. P< = 100 kWp Iberdrola (03/16).

Relé de máxima tensión homopolar. Para actuar en el interruptor automático de la instalación de generación.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Autoconsumo, esquema unifilar A.T. según MT 3.53.01. Ed. 05. P > = 100 kWp Iberdrola (03/16).

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Fuente pixabay.com

Potencia contratada = 600 kW 3 transformadores de 250 kVA

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Fuente pixabay.com

Potencia contratada = 600 kW 3 transformadores de 250 kVA

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Fuente pixabay.com

Potencia contratada = 600 kW 3 transformadores de 250 kVA

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Normativa autoconsumo RD 900/2015, breve resumen

Cargos variables transitorios (kWh) Según la energía consumida y autoproducida, en función de tarifa horaria. Exenciones: Clientes con Potencia Contratada ≤ 10 kW & Tipo 1 Islas Canarias, Ceuta y Melilla, Ibiza & Formentera Reducción de los cargos: Mallorca y Menorca

Cargos fijos (kW) Si ≤ 100kWp y no hay acumulación Si hay acumulación,

No hay cargos fijos Aplicable si potencia requerida > potencia contratada

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Normativa autoconsumo RD 900/2015, breve resumen Cargos fijos (kW) Si ≤ 100kWp y no hay acumulación Si hay acumulación,

No hay cargos fijos Aplicable si potencia requerida > potencia contratada

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Normativa autoconsumo RD 900/2015 Energia comprada de la red

Si hay contador en punto frontera

Demanda horaria = Saldo neto horario de energía medida en el punto frontera

Contador Producción FV

Contador Punto frontera

En todo caso se considerará nulo cuando el valor sea negativo. 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

¿Inyección cero? ¿Que ventajas hay con la inyección 0?

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Normativa autoconsumo RD 900/2015 Potencia de aplicación de cargos

SIN contador de consumo y sin baterías (no gestionables ) La potencia de aplicación de cargos en un periodo tarifario se usa los datos del contador del punto frontera Contador Producción FV

En todo caso se considerará nulo cuando el valor sea negativo. 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Normativa autoconsumo RD 900/2015 Costes de estudios de acceso y conexión

Tarifas Endesa

Tipo de conexión

Potencia (kW)

AUTOCONSUMO (*)

DIRECTA A RED

0 generación). Singularidad: -Picos de consumo hasta 1,2MW en verano. -Proyecto de ampliación de potencia contratada en marcha. -La FV minimiza los excesos y evita penalizaciones. Rentabilidad real de 5 años: kWh evitados + reducción excesos + ventajas fiscales. 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Gama Inversores PIKO

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Inversores monofásicos Modelo de inversor

1.5 MP

2.0 MP

Potencia nominal

1,5kW

2kW

Rango tensión PMP Max. Tensión entrada

2.5 MP

3.0 MP

3kW 1,52,5kW kW / 2kW

3,68KW

4,2kW

125 ... 500 V

350 ... 700 V

420 Voc

600 Voc

845 Voc

11,5 Amp.

12 Amp.

Seguidor PMP

1

Eficiencia max.

≥ 98%

Aislamiento Grado de protección

4.2 MP

75 ... 350 V

Corrient max. Entrada

Peso

3.6 MP

Sin transformador 8,3 kg

9,6 kg

9,1 kg

IP 21 (Instalación interior)

Interruptor CC 5 años de garantía (opcional 10, 15 o 20)

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Inversores monofásicos

Comunicaciones Integradas Ethernet (1x RJ45) RS485 bus (2 x RJ45) Modbus RTU (1x RJ11) (para medidores energéticos) Display grafico Datalogger y servidor Web PIKO Solar Portal Web gratuito

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Inversores monofásicos

Listado de los medidores de energía compatible con los PIKO MP y seleccionable desde el propio display del inversor: Empresa: Modelo: Part number:

Herholdt Controls ECS3 ECSEM72 (similar to Janitza ECS3)

Empresa: Modelo: Part number:

Janitza ECS3 ECSEM68MID (similar to Herholdt ECS3)

Empresa: Modelo: Part number:

B + GE Tech (o Eastron) SDM630 1141103

Empresa: Modelo: Part number:

Carlo Gavazzi EM24 EM24-DIN.AV9.3.X.IS.X

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Esquema conexión Conexión del medidor energético para medición de la energía consumida con PIKO MP.

Modbus RTU

Medidor energético

* Esquema valido únicamente con la gama de inversores monofásicos PIKO MP ( 1.5 | 2.0 | 2.5 | 3.0 | 3.6 | 4.2 )

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Instalación PIKO MP Conexiones AC/DC Sin necesidad de abrir el inversor. Todos los conectores son accesible desde fuera. Incluso los de comunicación, que se sitúan debajo del display.

Conector AC: Conector Wieland RST 25i3

Conectores DC: Phoenix Contact SUNCLIX (¡No se necesita herramienta de crimpar!)

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Redes de 220Vac entre fases

Símbolo Clase de protección II y marcado CE

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Conexiones PIKO MP Conexiones de comunicaciones Modbus RTU (para medidores de energía)

RJ11

Ethernet

RJ45

RS485-bus

RJ45 (2 puertos)

Conexiones de potencia Conector AC

Wieland RST 25i3

Conectores DC

Phoenix Contact SUNCLIX

DC-Switch

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Conexión LAN

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Solución sencilla al Wi-Fi Power 2 line

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Datos con acceso LAN y Display Desde el display, o con acceso LAN, se ven los datos siguientes:

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Menú display Rendimiento Diario

Mensual

Anual

Total

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Graficas de producción Energia anual

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Graficas de producción Potencia diaria

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Novedad Inversores monofásicos PIKO Solar Portal gratuito

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

En breve se actualizara el PORTAL Para ver las curvas de consumo, producción, diurno, etc

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Trifásicos PIKO BA Sensor

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Nueva generación PIKO

Nueva generación de inversores PIKO Gama de 3 kW hasta 20 kW AC Eficiencia mejorada (hasta 98%) Tensión de entrada hasta 1000V CC Compatible EEBus (Smart Home) Compatible con sensor de consumo PIKO BA Sensor de KOSTAL (modelos trifásicos) Señal autoconsumo (activación de carga) Nuevo interruptor CC robusto y práctico Manejo fácil con las asas laterales empotradas Inversor strings, entradas CC independientes Comunicaciones integradas (RJ45, RS485, etc) Portal Web gratuito PIKO APP gratuita Etc.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Nueva generación PIKO

Tipo de inversor

PIKO Unidades

3.0

4.2

4.6

5.5

7.0

8.5

10

12

15

17

20

Lado de entrada (CC) Nº entradas CC / Nº MPPT

1/1

2/2

3/3

Tensión de entrada máx.

V

900

1000

Tensión de entrada nominal

V

400

680

Tensión de entrada mín.

V

Corriente de entrada máx.

A

12,5

Corriente de entrada máx. con conexión en paralelo

A





kW

3 1~AC 230V

4,2

96,2

97,5

160 / 180 (iniciar) sim: 18/18 asim: 20/10

11

22 (CC1+CC2)

sim.: 20 / 20 / 20 asim.: 20 / 20 / 10

36(CC1+CC2)

40(CC1+CC2) 20(CC3)

10

15

Lado de salida Potencia nominal Nº fases & tensión nominal de la red

Grado de eficiencia máx.

%

Topologia

4,6

5,5

7

8,5

12

17

20

3~/N/PE CA 400V

97,7

97,6

97,7

98

Sin separación galvánica, sin transformador / Sem separação galvânica, sem transformador

Tipo de protección IP PIKO BA Sensor Interface Garantia (años/anos)



IP55 (interior & exterior) 1 5 (opcional: 10/20)

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Nueva generación PIKO Monofásico

PIKO 3.0 Inversor monofásico Potencia nom. CA: 3000 W Rango de entrada: 160 V- 900 V Rango MPP: 200 – 700V 1 Seguidor PMP 12,5 A de entrada Peso: 22Kg Medidas: 385 x 500 x 222 mm

Nota: Limitación de la potencia nominal configurable en todos los inversores PIKO.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Nueva generación PIKO

Inversores trifásicos

PIKO 4.2 … 8.5 KW

PIKO 10 / 12 kW

PIKO 15 / 17 / 20 kW

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Nueva generación PIKO Trifásico

PIKO 4.2 / 4.6 / 5.5 / 7.0 / 8.5 Rango de entrada: 160 V - 1000 V Rango PMP: 290 – 800V Hasta 2 Seguidor PMP (PIKO 4.2 con 1 PMP) 11A por entrada 97,7% eficiencia máx. Conexión PIKO BA Sensor Peso: ± 25Kg Medidas: 385 x 500 x 236 mm

Nota: Limitación de la potencia nominal configurable en todos los inversores PIKO.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Nueva generación PIKO Trifásico

PIKO 10 / 12 Rango de entrada: 160 V - 1000 V Rango PMP: 290 – 800V 2 Seguidor PMP Hasta 36A de entrada 97,7% eficiencia máx. Conexión PIKO BA Sensor Peso: 37,5Kg Medidas: 385 x 500 x 222 mm

Nota: Limitación de la potencia nominal configurable en todos los inversores PIKO.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Nueva generación PIKO Trifásico

PIKO 15 / 17 / 20 Rango de entrada: 160 V - 1000 V Rango PMP: 295 – 800V 3 Seguidor PMP Hasta 60A de entrada (20A/entrada) 98% eficiencia máx. Conexión PIKO BA Sensor Peso: 48,5 Kg Medidas: 540 x 700 x 265 mm

Nota: Limitación de la potencia nominal configurable en todos los inversores PIKO.

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Ficha técnica Lado CC - Entrada PIKO 10 entradas en simétrico (18A/18A)

MPP1

MPP2

23

22

PIKO 12 entradas en asimétrico (20A/10A)

MPP1

20

@70ºC

Corriente Isc

Tensión UMPP



MPP1

9A290V



MPP2

9A290V

MPP2

20

10

@70ºC

Corriente Isc

Tensión UMPP



MPP1

18A490V



MPP2

9A250V

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Ficha técnica Lado CC - Entrada PIKO 10 entradas en asimétrico (20A/10A)

MPP1

23



MPP2

PIKO 12 entradas en asimétrico (20A/10A)

MPP1

20

23 @70ºC

Corriente Isc

Tensión UMPP

MPP1

18A390V

MPP2

20

10

@70ºC

Corriente Isc

Tensión UMPP



MPP1

18A490V



MPP2

9A250V

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Ficha técnica Lado CC - Entrada PIKO 10 entradas en paralelo (18A+18A = 36A)

MPP1

MPP2

PIKO 12 entradas en asimétrico (20A/10A)

MPP1

MPP2

Shunt interno

23



20

23 @70ºC

Corriente Isc

Tensión UMPP

MPP1+2

18A290V

20

10

@70ºC

Corriente Isc

Tensión UMPP



MPP1

18A490V



MPP2

9A250V

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Ficha técnica Lado CC - Entrada PIKO 12 entradas en paralelo (18A+18A = 36A)

MPP1

MPP2

PIKO 12 entradas en asimétrico (20A/10A)

MPP1

MPP2

Shunt interno

23



23

20

23

@70ºC

Corriente Isc

Tensión UMPP

MPP1+2

27A345V

20

10

@70ºC

Corriente Isc

Tensión UMPP



MPP1

18A490V



MPP2

9A250V

23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.

Ficha técnica Lado CC - Entrada PIKO 15 entradas en simétrico (20A/20A/20A)

MPP1

21 0

MPP2

23

MPP3

20

PIKO 15 entradas en simétrico (20A/20A/20A)

MPP1

10

MPP2

10

11

MPP3

11

12

12

@70ºC

Corriente Isc

Tensión UMPP



MPP1

18A260V

575V>260V



MPP2

18A260V

522V>260V



MPP3

18A260V

@70ºC

Corriente Isc

Tensión UMPP



MPP1

9A260V



MPP2

9A345V



MPP3

18A260V

@70ºC

Corriente Isc

Tensión UMPP



MPP1

18A345V



MPP2

9A

Get in touch

Social

© Copyright 2013 - 2024 MYDOKUMENT.COM - All rights reserved.