Autoconsumo con y sin almacenamiento bajo el RD 900/2015 Septiembre 2016
Jean-Francois Picard
[email protected] KOSTAL Solar Electric Ibérica S.L. www.kostal-solar-electric.com
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Agenda Breve presentación de la empresa KOSTAL Introducción al autoconsumo FV según el RD 900/2015 Aspectos legales Esquemas conexionado Dimensionado Ejemplo Autoconsumo tipo 2 Gama de inversores PIKO Monofásico (desde 1,5 kW hasta 4,2 kW) Trifásicos (desde 4,2 kW hasta 20 kW) PIKO BA Sensor, Sensor de corriente de consumos PIKO Battery: Autoconsumo con almacenamiento Monitorización PIKO Solar Portal PIKO App
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Presentación de la empresa
Presencia global 15,000 empleados 39 direcciones 17 países 4 continentes 2.000 m€
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Presentación de la empresa
KOSTAL Automobile Electrical
Módulos de techo, de columna de dirección, de consola central Sistemas eléctrico de tablero Controladores de puertas Controladores de asientos Elementos de control e interruptores
KOSTAL Industrial electronics KOSTAL Kontakt Systeme
KOSTAL Industrie Elektrik
KOSTAL SOMA
Sistemas de contacto Sistemas de conexión y enchufes
Cajas de módulo fotovoltaico Variadores frecuencia Electrónica de control y medición Inversores fotovoltaicos
Automatización Tecnología de pruebas Tecnología de medición
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Presentación de la empresa
KOSTAL Automobile Electrical
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Presentación de la empresa
KOSTAL Automobile Electrical
El éxito de nuestros clientes asegura el éxito de KOSTAL! 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Presentación de la empresa
KOSTAL Industrie Fotovoltaica
Electrónica de potencia y control de motores Inversores fotovoltaicos PIKO
Electrónica de control
KOSTAL Solar Electric GmbH
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Presentación de la compañía Presentación
de la empresa
Hagen, Alemania Oficina central de KOSTAL Industrial Electronics Desde Abril 2005 Superficie de 87,000 m², de los cuales 14,700 m² están edificados. Aprox. 450 empleados (más de 200 en KOSTAL Industrial Electronics, el resto en KOSTAL Kontakt Systeme GmbH)
Hagen Schalksmühle Guyancourt
Freiburg i.Br.
Turin
Thessaloniki Valencia
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Presentación de la empresa
Valencia, España KOSTAL Solar Electric Ibérica S.L. Desde Enero de 2009 Oficina técnico comercial para los mercados de España y Portugal Ventas, Soporte técnico, Formación
Hagen Schalksmühle Guyancourt
Freiburg i.Br.
Turin
Thessaloniki Valencia
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Autoconsumo
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Autoconsumo
AUTOCONSUMO
VENTA A RED
Generación FV = Ahorro de energía
Generación = Venta de energía
Contador Producción
Tarifa de venta €/Kwh Vertidos a la red
kW Tarifa de compra € / kWh Tarifa de compra €/kWh (según contrato)
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Normativa autoconsumo RD 900/2015, breve resumen Modalidad Autoconsumo TIPO 1 Potencia contratada del cliente ≤ 100kW Los excedentes son permitidos, pero no remunerados 1 único titular (sujeto Consumidor) Instalación sujeta al RD 1699/2011 Sin registro en el RAIPRE (Registro Autonómico de Instalaciones de Producción en Régimen Especial) Sin Aval Modalidad Autoconsumo TIPO 2 Sin mínimos, ni máximos de potencia contratada del cliente Los excedentes son permitidos, y remunerados a precio pool Titular Consumidor puede diferir del titular Productor (pero un único titular Productor) Instalaciones ≤ 100kW FVp sujetas al RD 1699/2011 Instalaciones >100kW FVp sujetas al RD1955/2000 (y medición de consumo total) Con registro en el RAIPRE (Registro Autonómico de Instalaciones de Producción en Régimen Especial) Aval (10 €/kW) Y en cualquier caso Potencia FVp ≤ Potencia contratada del cliente Medición de la producción FV (telegestión y telemedida.) Registro de Autoconsumidores (MINETUR) 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Normativa autoconsumo RD 900/2015, breve resumen Acumulación Tanto para la modalidad TIPO 1 como TIPO 2, se permite explícitamente el uso de baterías. Estas instalaciones se denominan “gestionables”. Se asocia unos cargos específicos a las instalaciones “gestionables”. Pero este caro solamente se aplicara cuando se consume más de la potencia contratada!
Instalación FV aislada No se aplica a las instalaciones aisladas de la red (¡sin conexión física alguna!) Art. 3.1.j): aquella en la que no existe en ningún momento capacidad física de conexión eléctrica con la red de transporte o distribución ni directa ni indirectamente a través de una instalación propia o ajena. Las instalaciones desconectadas de la red mediante dispositivos interruptores o equivalentes no se considerarán aisladas a los efectos de la aplicación de este real decreto.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Normativa autoconsumo RD 900/2015, breve resumen
RD 900/2015 Autoconsumidor tipo 1 : Consumidor Pp ≤ Pc ≤ 100kW RD 1699/2011
Autoconsumidor tipo 2 : Consumidor y Productor RD 1699/2011 ( Pp ≤ 100 kW) RD 1955/2000 (Pp > 100 kW) – Ley 54/1997 RD 413/2014 (RAIPRE)
Distribuidora eléctrica Autoconsumidor B.T. Pc < 100kW
Autoconsumidor A.T. Pc ≤ 100 kW Pc > 100 kW
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Normativa autoconsumo RD 900/2015 Equipos de mediciones
Tipo 1 Contador de producción obligatorio Contador punto frontera obligatorio Contador consumo opcional
Contador Producción FV
Contador Punto frontera
Contador Consumos
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Autoconsumo, esquema unifilar B.T. según MT 3.53.01. Ed. 05. Iberdrola (03/16)
Para la conexión de una instalación de generación a la red de Iberdrola Distribución de Baja Tensión se aplicará las condiciones técnicas de conexión y funcionamiento recogidas en el Real Decreto 1699/2011 que regula la conexión a red de instalaciones de producción de pequeña potencia.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Tipo 2 Si ≤ 100kWp & 1 solo titular (consumidor = productor) Contador consumo opcional Contador punto frontera obligatorio Contador Producción FV
Normativa autoconsumo RD 900/2015 Equipos de mediciones Otros casos… Contador consumo obligatorio Contador punto frontera opcional Contador Producción FV
Contador Punto frontera
Contador Consumos
Contador Punto frontera
Contador Consumos
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Autoconsumo, esquema unifilar A.T. según MT 3.53.01. Ed. 05. P< = 100 kWp Iberdrola (03/16).
Relé de máxima tensión homopolar. Para actuar en el interruptor automático de la instalación de generación.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Autoconsumo, esquema unifilar A.T. según MT 3.53.01. Ed. 05. P > = 100 kWp Iberdrola (03/16).
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Fuente pixabay.com
Potencia contratada = 600 kW 3 transformadores de 250 kVA
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Fuente pixabay.com
Potencia contratada = 600 kW 3 transformadores de 250 kVA
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Fuente pixabay.com
Potencia contratada = 600 kW 3 transformadores de 250 kVA
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Normativa autoconsumo RD 900/2015, breve resumen
Cargos variables transitorios (kWh) Según la energía consumida y autoproducida, en función de tarifa horaria. Exenciones: Clientes con Potencia Contratada ≤ 10 kW & Tipo 1 Islas Canarias, Ceuta y Melilla, Ibiza & Formentera Reducción de los cargos: Mallorca y Menorca
Cargos fijos (kW) Si ≤ 100kWp y no hay acumulación Si hay acumulación,
No hay cargos fijos Aplicable si potencia requerida > potencia contratada
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Normativa autoconsumo RD 900/2015, breve resumen Cargos fijos (kW) Si ≤ 100kWp y no hay acumulación Si hay acumulación,
No hay cargos fijos Aplicable si potencia requerida > potencia contratada
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Normativa autoconsumo RD 900/2015 Energia comprada de la red
Si hay contador en punto frontera
Demanda horaria = Saldo neto horario de energía medida en el punto frontera
Contador Producción FV
Contador Punto frontera
En todo caso se considerará nulo cuando el valor sea negativo. 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
¿Inyección cero? ¿Que ventajas hay con la inyección 0?
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Normativa autoconsumo RD 900/2015 Potencia de aplicación de cargos
SIN contador de consumo y sin baterías (no gestionables ) La potencia de aplicación de cargos en un periodo tarifario se usa los datos del contador del punto frontera Contador Producción FV
En todo caso se considerará nulo cuando el valor sea negativo. 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Normativa autoconsumo RD 900/2015 Costes de estudios de acceso y conexión
Tarifas Endesa
Tipo de conexión
Potencia (kW)
AUTOCONSUMO (*)
DIRECTA A RED
0 generación). Singularidad: -Picos de consumo hasta 1,2MW en verano. -Proyecto de ampliación de potencia contratada en marcha. -La FV minimiza los excesos y evita penalizaciones. Rentabilidad real de 5 años: kWh evitados + reducción excesos + ventajas fiscales. 23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Gama Inversores PIKO
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Inversores monofásicos Modelo de inversor
1.5 MP
2.0 MP
Potencia nominal
1,5kW
2kW
Rango tensión PMP Max. Tensión entrada
2.5 MP
3.0 MP
3kW 1,52,5kW kW / 2kW
3,68KW
4,2kW
125 ... 500 V
350 ... 700 V
420 Voc
600 Voc
845 Voc
11,5 Amp.
12 Amp.
Seguidor PMP
1
Eficiencia max.
≥ 98%
Aislamiento Grado de protección
4.2 MP
75 ... 350 V
Corrient max. Entrada
Peso
3.6 MP
Sin transformador 8,3 kg
9,6 kg
9,1 kg
IP 21 (Instalación interior)
Interruptor CC 5 años de garantía (opcional 10, 15 o 20)
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Inversores monofásicos
Comunicaciones Integradas Ethernet (1x RJ45) RS485 bus (2 x RJ45) Modbus RTU (1x RJ11) (para medidores energéticos) Display grafico Datalogger y servidor Web PIKO Solar Portal Web gratuito
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Inversores monofásicos
Listado de los medidores de energía compatible con los PIKO MP y seleccionable desde el propio display del inversor: Empresa: Modelo: Part number:
Herholdt Controls ECS3 ECSEM72 (similar to Janitza ECS3)
Empresa: Modelo: Part number:
Janitza ECS3 ECSEM68MID (similar to Herholdt ECS3)
Empresa: Modelo: Part number:
B + GE Tech (o Eastron) SDM630 1141103
Empresa: Modelo: Part number:
Carlo Gavazzi EM24 EM24-DIN.AV9.3.X.IS.X
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Esquema conexión Conexión del medidor energético para medición de la energía consumida con PIKO MP.
Modbus RTU
Medidor energético
* Esquema valido únicamente con la gama de inversores monofásicos PIKO MP ( 1.5 | 2.0 | 2.5 | 3.0 | 3.6 | 4.2 )
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Instalación PIKO MP Conexiones AC/DC Sin necesidad de abrir el inversor. Todos los conectores son accesible desde fuera. Incluso los de comunicación, que se sitúan debajo del display.
Conector AC: Conector Wieland RST 25i3
Conectores DC: Phoenix Contact SUNCLIX (¡No se necesita herramienta de crimpar!)
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Redes de 220Vac entre fases
Símbolo Clase de protección II y marcado CE
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Conexiones PIKO MP Conexiones de comunicaciones Modbus RTU (para medidores de energía)
RJ11
Ethernet
RJ45
RS485-bus
RJ45 (2 puertos)
Conexiones de potencia Conector AC
Wieland RST 25i3
Conectores DC
Phoenix Contact SUNCLIX
DC-Switch
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Conexión LAN
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Solución sencilla al Wi-Fi Power 2 line
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Datos con acceso LAN y Display Desde el display, o con acceso LAN, se ven los datos siguientes:
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Menú display Rendimiento Diario
Mensual
Anual
Total
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Graficas de producción Energia anual
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Graficas de producción Potencia diaria
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Novedad Inversores monofásicos PIKO Solar Portal gratuito
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
En breve se actualizara el PORTAL Para ver las curvas de consumo, producción, diurno, etc
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Trifásicos PIKO BA Sensor
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Nueva generación PIKO
Nueva generación de inversores PIKO Gama de 3 kW hasta 20 kW AC Eficiencia mejorada (hasta 98%) Tensión de entrada hasta 1000V CC Compatible EEBus (Smart Home) Compatible con sensor de consumo PIKO BA Sensor de KOSTAL (modelos trifásicos) Señal autoconsumo (activación de carga) Nuevo interruptor CC robusto y práctico Manejo fácil con las asas laterales empotradas Inversor strings, entradas CC independientes Comunicaciones integradas (RJ45, RS485, etc) Portal Web gratuito PIKO APP gratuita Etc.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Nueva generación PIKO
Tipo de inversor
PIKO Unidades
3.0
4.2
4.6
5.5
7.0
8.5
10
12
15
17
20
Lado de entrada (CC) Nº entradas CC / Nº MPPT
1/1
2/2
3/3
Tensión de entrada máx.
V
900
1000
Tensión de entrada nominal
V
400
680
Tensión de entrada mín.
V
Corriente de entrada máx.
A
12,5
Corriente de entrada máx. con conexión en paralelo
A
–
–
kW
3 1~AC 230V
4,2
96,2
97,5
160 / 180 (iniciar) sim: 18/18 asim: 20/10
11
22 (CC1+CC2)
sim.: 20 / 20 / 20 asim.: 20 / 20 / 10
36(CC1+CC2)
40(CC1+CC2) 20(CC3)
10
15
Lado de salida Potencia nominal Nº fases & tensión nominal de la red
Grado de eficiencia máx.
%
Topologia
4,6
5,5
7
8,5
12
17
20
3~/N/PE CA 400V
97,7
97,6
97,7
98
Sin separación galvánica, sin transformador / Sem separação galvânica, sem transformador
Tipo de protección IP PIKO BA Sensor Interface Garantia (años/anos)
–
IP55 (interior & exterior) 1 5 (opcional: 10/20)
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Nueva generación PIKO Monofásico
PIKO 3.0 Inversor monofásico Potencia nom. CA: 3000 W Rango de entrada: 160 V- 900 V Rango MPP: 200 – 700V 1 Seguidor PMP 12,5 A de entrada Peso: 22Kg Medidas: 385 x 500 x 222 mm
Nota: Limitación de la potencia nominal configurable en todos los inversores PIKO.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Nueva generación PIKO
Inversores trifásicos
PIKO 4.2 … 8.5 KW
PIKO 10 / 12 kW
PIKO 15 / 17 / 20 kW
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Nueva generación PIKO Trifásico
PIKO 4.2 / 4.6 / 5.5 / 7.0 / 8.5 Rango de entrada: 160 V - 1000 V Rango PMP: 290 – 800V Hasta 2 Seguidor PMP (PIKO 4.2 con 1 PMP) 11A por entrada 97,7% eficiencia máx. Conexión PIKO BA Sensor Peso: ± 25Kg Medidas: 385 x 500 x 236 mm
Nota: Limitación de la potencia nominal configurable en todos los inversores PIKO.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Nueva generación PIKO Trifásico
PIKO 10 / 12 Rango de entrada: 160 V - 1000 V Rango PMP: 290 – 800V 2 Seguidor PMP Hasta 36A de entrada 97,7% eficiencia máx. Conexión PIKO BA Sensor Peso: 37,5Kg Medidas: 385 x 500 x 222 mm
Nota: Limitación de la potencia nominal configurable en todos los inversores PIKO.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Nueva generación PIKO Trifásico
PIKO 15 / 17 / 20 Rango de entrada: 160 V - 1000 V Rango PMP: 295 – 800V 3 Seguidor PMP Hasta 60A de entrada (20A/entrada) 98% eficiencia máx. Conexión PIKO BA Sensor Peso: 48,5 Kg Medidas: 540 x 700 x 265 mm
Nota: Limitación de la potencia nominal configurable en todos los inversores PIKO.
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Ficha técnica Lado CC - Entrada PIKO 10 entradas en simétrico (18A/18A)
MPP1
MPP2
23
22
PIKO 12 entradas en asimétrico (20A/10A)
MPP1
20
@70ºC
Corriente Isc
Tensión UMPP
✓
MPP1
9A290V
✓
MPP2
9A290V
MPP2
20
10
@70ºC
Corriente Isc
Tensión UMPP
✓
MPP1
18A490V
✓
MPP2
9A250V
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Ficha técnica Lado CC - Entrada PIKO 10 entradas en asimétrico (20A/10A)
MPP1
23
✓
MPP2
PIKO 12 entradas en asimétrico (20A/10A)
MPP1
20
23 @70ºC
Corriente Isc
Tensión UMPP
MPP1
18A390V
MPP2
20
10
@70ºC
Corriente Isc
Tensión UMPP
✓
MPP1
18A490V
✓
MPP2
9A250V
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Ficha técnica Lado CC - Entrada PIKO 10 entradas en paralelo (18A+18A = 36A)
MPP1
MPP2
PIKO 12 entradas en asimétrico (20A/10A)
MPP1
MPP2
Shunt interno
23
✓
20
23 @70ºC
Corriente Isc
Tensión UMPP
MPP1+2
18A290V
20
10
@70ºC
Corriente Isc
Tensión UMPP
✓
MPP1
18A490V
✓
MPP2
9A250V
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Ficha técnica Lado CC - Entrada PIKO 12 entradas en paralelo (18A+18A = 36A)
MPP1
MPP2
PIKO 12 entradas en asimétrico (20A/10A)
MPP1
MPP2
Shunt interno
23
✓
23
20
23
@70ºC
Corriente Isc
Tensión UMPP
MPP1+2
27A345V
20
10
@70ºC
Corriente Isc
Tensión UMPP
✓
MPP1
18A490V
✓
MPP2
9A250V
23.09.2016, KOSTAL Solar Electric Ibérica S.L. Contents and presentation are protected world-wide. Any kind of using, copying etc. is prohibited without prior permission. All rights - incl. Industrial property rights - are reserved.
Ficha técnica Lado CC - Entrada PIKO 15 entradas en simétrico (20A/20A/20A)
MPP1
21 0
MPP2
23
MPP3
20
PIKO 15 entradas en simétrico (20A/20A/20A)
MPP1
10
MPP2
10
11
MPP3
11
12
12
@70ºC
Corriente Isc
Tensión UMPP
✓
MPP1
18A260V
575V>260V
✓
MPP2
18A260V
522V>260V
✓
MPP3
18A260V
@70ºC
Corriente Isc
Tensión UMPP
✓
MPP1
9A260V
✓
MPP2
9A345V
✓
MPP3
18A260V
@70ºC
Corriente Isc
Tensión UMPP
✓
MPP1
18A345V
✓
MPP2
9A