ESPECIFICACIONES TECNICAS OPERATING TEMPERATURE RANGE
DIELECTRIC STRENGTH
CONTINUOUS INTERMITTENT
ASTM D-149
-54°C TO +260°C (-65°F to +500°F) -65°C TO +260°C (-85°F to +500°F)
0.010" - 0.030" 400 VPM
MINIMUM
0.040" 300 VPM
Short TIME
0.050" 275 VPM
(1/4: Electrodes)
0.060" 250 VPM 0.070" - 0.080” 200 VPM
DIELECTRIC CONSTANT, 1 KHZ
2.95
DISSIPATION FACTOR, 1 KHZ
< .0004
VOLUME RESISTIVITY
ASTM D-257
3 x 1014 OHM/CM
COLD BRITTLE POINT, MAX
ASTM D-2137
-65°C
WATER ABSORPTION
FED, STD, 601, METHOD 6251
3% MAX BY WEIGHT
TENSILE STRENGTH
ASTM D-412
700 PSI MINIMUM
ULTIMATE ELONGATION
ASTM D-412
300% MINIMUM
AGING PROPERTY
ASTM D-412
Retention (100 Hrs @ 500°F) TENSILE
75%
ELONGATION
50%
TEAR RESISTANCE DUROMETER HARDNESS
85 PSI 50 SHORE DUROMETER (ROOM CURED 24 HOURS)
TOLERANCES
THICKNESS +/-.002" WIDTH +/-.0625"
www.grunecorp.com
[email protected]
RESISTENCIA QUIMICA BANDA SELLADO ALTA RESISTENCIA SOLUCION MULTI-PROPOSITO PARA APLICACIONES MINERAS
Las bandas de sellado poseen excelente resistencia a una variedad de químicos, fluidos y aceites así como también en aplicaciones de alto voltaje. En aplicaciones con ácidos, álcalis diluidos y soluciones salinas, ya sea con alta temperatura o en frio, las bandas presentan efectos mínimos. Ácidos y álcalis concentrados pueden afectan las propiedades de las bandas especialmente ácidos oxidantes como el ácido sulfúrico. Líquidos polares, como alcoholes de cadena corta y acetonas pueden causar hinchamiento de la banda sin embargo pueden ser utilizadas con la correcta aplicación. En aplicaciones de líquidos apolares, lineales o hidrocarburos cíclicos, alifáticos o aceites minerales y gasolinas las bandas pueden ser utilizadas en áreas con menor superficie de exposición al fluido. La siguiente tabla muestra el listado de químicos con los que han sido testeadas las bandas y sus efectos durante 336 horas continuas de aplicación en sumergencia total a una temperatura de 49°C (120°F).
IMMERSION LIQUID Acetic Acid 10%
EXPOSURE TIME 336 hrs
Acetic Acid 20%
336 hrs
Acetic Acid Concentrated
336 hrs
Acetone Ammonium Hydroxide 10% Ammodium Hydroxide Concentrated
336 hrs 336 hrs 336 hrs
Aviation Fuel
336 hrs
Benzene
336 hrs
Boric Acid 20% Calcium Chloride in H20 Carbon Tetrachloride
336 hrs 336 hrs 336 hrs
Diesel Fuel
336 hrs
Distilled Water
336 hrs
Ethylene Glycol Fatty Acids (Linseed Oil) Formic Acid 10% www.grunecorp.com
336 hrs 336 hrs 336 hrs
TEMP
OBSERVATION
Room Temp
No Effect
120F
No Effect
Room Temp
No Effect
120F
No Effect
Room Temp
No Effect
120F
Slight Cracking
Room Temp
Slight Discoloration
120F
Slight Discoloration
Room Temp
No Effect
120F
No Effect
Room Temp
Very Slight Discoloration
120F
Very Slight Discoloration
Room Temp
Slight Discoloration, severe swelling
120F
Not Tested
Room Temp
Slight Discoloration, severe swelling
120F
Not Tested
Room Temp
No Effect
120F
No Effect
Room Temp
No Effect
120F
No Effect
Room Temp
No Effect
120F
No Effect
Room Temp
Slight Discoloration, severe swelling
120F
Not Tested
Room Temp
No Effect
120F
No Effect
Room Temp
No Effect
120F
No Effect
Room Temp
Slight Discoloration, severe swelling
120F
Slight Discoloration, severe swelling
Room Temp
No Effect
120F
No Effect
[email protected]
IMMERSION LIQUID Gasoline Glycerine Hydraulic Fluid Hydrochloric Acid 5% Hydrochloric Acid 10% Hydrochloric Acid 20% Hydrochloric Acid Concentrated Hydrogen Peroxide 10%
Kerosene
Methyl Alcohol
EXPOSURE TIME 336 hrs 336 hrs 336 hrs 336 hrs 336 hrs 336 hrs 336 hrs 336 hrs
336 hrs
336 hrs
Methyl Ethyl Ketone
336 hrs
Methyl Isobutyl Ketone
336 hrs
TEMP Room Temp
Slight Discoloration
120F
Not Tested
Room Temp
Discoloration
120F
Not Tested
Room Temp
Slight discoloration, slight swelling
120F
Not Tested
Room Temp
No Effect
120F
No Effect
Room Temp
No Effect
120F
No Effect
Room Temp
Discoloration & slight surface cracking
120F
Discoloration & slight surface cracking
Room Temp
No Effect
120F
No Effect
Room Temp
No Effect
120F
No Effect
Room Temp
336 hrs
Not Tested
Room Temp
No Effect
120F
No Effect
Room Temp
Slight Discoloration, severe swelling
120F
Not Tested
Room Temp
Slight Discoloration, severe swelling
Room Temp 120F
Motor Oil Nitric Acid 5% Nitric Acid 10% Phosphoric Acid 50% Potash Lye 20%
336 hrs 336 hrs 336 hrs 336 hrs 336 hrs
Soda Solution 20%
336 hrs
20% Sodium Chloride in H20
336 hrs
Sodium Hydroxide 50%
www.grunecorp.com
336 hrs
Slight Discoloration, moderate swelling
120F
120F Mineral Spirits
OBSERVATION
Not Tested Slight Discoloration, moderate swelling No Effect
Room Temp
Slight Discoloration
120F
Slight Discoloration, softening
Room Temp
No Effect
120F
No Effect
Room Temp
For both temps, slight discoloration
120F
and slightly increased pliability
Room Temp
No Effect
120F
No Effect
Room Temp
No Effect
120F
Slight Distention, surface alterations
Room Temp
No Effect
120F
Slight Distention, surface alterations
Room Temp
No Effect
120F
No Effect
Room Temp
Surface altered, extreme pliability
120F
Surface altered, increased pliability
[email protected]
IMMERSION LIQUID Sodium Hydroxide 50%
EXPOSURE TIME 336 hrs
Sodium Hypochlorite 1%
336 hrs
Sulfuric Acid 5%
336 hrs
Sulfuric Acid 10% Sulfuric Acid 25% Sulfuric Acid 50%
Toluene
336 hrs 336 hrs 336 hrs
336 hrs
TEMP Room Temp
Surface altered, extreme pliability
120F
Surface altered, increased pliability
Room Temp
No Effect
120F
No Effect
Room Temp
No Effect
120F
No Effect
Room Temp
Slight discoloration and cracking
120F
Slight discoloration and cracking
Room Temp
Discoloration & moderate cracking
120F
Discoloration & moderate cracking
Room Temp
Discoloration & severe cracking
120F
Discoloration & severe cracking
Room Temp 120F
Trichloroethane
Xylene
www.grunecorp.com
336 hrs
336 hrs
OBSERVATION
Room Temp
Slight Discoloration, moderate swelling Not Tested Slight Discoloration, moderate swelling
120F
Not Tested
Room Temp
Slightly increased pliability
120F
No Effect
[email protected]